CENELEC - Standards Development - List of Technical Bodies - CLC/TC 20

CLC/TC 20

Electric cables

 
export to xls file

CLC/TC 20 Work programme

sort up 
Project reference
sort upsort down
Current Code
sort upsort down
Document
Init. Date
sort upsort down
Current stage
sort upsort down
Next Stage
sort upsort down
Fcst. voting date
HD 603 S2:201X (pr=22561)
Distribution cables of rated voltage 0,6/1 kV
5099  2009-07-072013-03-112013-04-082012-05-31
HD 632 S3:201X (pr=22560)
Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV)
5099 2009-07-072013-02-112013-03-112012-06-30
prEN 50200:2013 (pr=23980)
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
4060 2012-01-172013-10-282013-11-18 
prEN 50393:2012 (pr=23490)
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
4060 2011-04-152012-10-162012-11-06 
FprEN 50575:2014 (pr=23570)
Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements
4099 2011-05-202014-02-12  
CLC/FprTS 50576:2014 (pr=24625)
Electric cables - Extended application of test results
5020 2012-12-182014-02-282014-05-02 
prEN 50577:2013 (pr=23694)
Electric cables - Fire resistance test for unprotected electric cables (P classification)
4060 2011-08-112014-04-072014-04-28 
prEN 50618:2013 (pr=24019)
Electric cables for photovoltaic systems
4060 2012-02-082014-01-132014-02-03 
prEN 50620:2014 (pr=24105)
Electric cables - Charging cables for electric vehicles
4020 2012-03-092014-02-072014-07-11 
EN 60332-1-1:2004/FprA1:2014 (pr=25349)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
5020  2014-02-172014-04-182014-07-18 
EN 60332-1-2:2004/FprA1:2014 (pr=25350)
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
5020  2014-02-172014-04-182014-07-18 
EN 60332-1-3:2004/FprA1:2014 (pr=25351)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
5020  2014-02-172014-04-182014-07-18 
EN 60702-1:2002/FprA1:2013 (pr=24586)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
5060  2012-11-282013-12-022013-12-23 
EN 60702-2:2002/FprA1:2013 (pr=24587)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations
5060  2012-11-282013-12-022013-12-23 
FprEN 60885-3:2013 (pr=24974)
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
5060  2013-07-292014-01-132014-02-03 

export to xls file

CLC/TC 20 Publications

Reference, Title
sort up  
Publication date
Downloads
CLC/TR 62125:2008 (pr=21391)
Environmental statement specific to TC 20 - Electric cables
2008-04-16 export to doc file  EN  FR  DE
EN 50143:2009 (pr=15931)
Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
2009-03-26 export to doc file  EN  FR  DE
EN 50200:2006 (pr=15324)
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
2006-05-19 export to doc file  EN  FR  DE
EN 50214:2006 (pr=11537)
Flat polyvinyl chloride sheathed flexible cables
2006-11-22 export to doc file  EN  FR  DE
EN 50262:1998 (pr=313)
Cable glands for electrical installations
1998-09-25 export to doc file  EN
EN 50262:1998/A1:2001 (pr=11600)
Cable glands for electrical installations
2001-08-23 export to doc file  EN
EN 50262:1998/A2:2004 (pr=14575)
Cable glands for electrical installations
2004-12-14 export to doc file  EN  FR  DE
EN 50264-1:2008 (pr=14587)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
2008-06-27 export to doc file  EN  FR  DE
EN 50264-2-1:2008 (pr=15251)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
2008-06-27 export to doc file  EN  FR  DE
EN 50264-2-2:2008 (pr=15252)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
2008-06-27 export to doc file  EN  FR  DE
EN 50264-3-1:2008 (pr=15253)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
2008-06-27 export to doc file  EN  FR  DE
EN 50264-3-2:2008 (pr=15254)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
2008-06-27 export to doc file  EN  FR  DE
EN 50267-1:1998 (pr=5256)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
1998-06-17 export to doc file  EN
EN 50267-2-1:1998 (pr=6701)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
1998-06-17 export to doc file  EN
EN 50267-2-2:1998 (pr=7132)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
1998-06-17 export to doc file  EN
EN 50267-2-3:1998 (pr=7133)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
1998-06-17 export to doc file  EN
EN 50305:2002 (pr=7064)
Railway applications - Railway rolling stock cables having special fire performance - Test methods
2002-07-19 export to doc file  EN
EN 50306-1:2002 (pr=11548)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
2002-10-30 export to doc file  EN
EN 50306-2:2002 (pr=11549)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
2002-10-30 export to doc file  EN
EN 50306-3:2002 (pr=11550)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
2002-10-31 export to doc file  EN
EN 50306-4:2002 (pr=11551)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
2002-10-31 export to doc file  EN
EN 50307:2002 (pr=7325)
Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables
2002-12-10 export to doc file  EN
EN 50334:2001 (pr=13166)
Marking by inscription for the identification of cores of electric cables
2001-04-12 export to doc file  EN
EN 50355:2003 (pr=7063)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use
2003-09-26 export to doc file  EN  FR  DE
EN 50355:2013 (pr=24390)
Railway applications - Railway rolling stock cables having special fire performance - Guide to use
2013-08-30 export to doc file  EN  FR
EN 50362:2003 (pr=14003)
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
2003-02-07 export to doc file  EN  FR  DE
EN 50363-0:2011 (pr=22552)
Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
2011-03-18 export to doc file  EN  FR  DE
EN 50363-10-1:2005 (pr=15061)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
2005-11-25 export to doc file  EN  FR  DE
EN 50363-10-2:2005 (pr=15062)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
2005-11-25 export to doc file  EN  FR  DE
EN 50363-1:2005 (pr=15050)
Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-2-1:2005 (pr=15051)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-2-1:2005/A1:2011 (pr=22553)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
2011-03-18 export to doc file  EN  FR  DE
EN 50363-2-2:2005 (pr=15052)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-3:2005 (pr=15053)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-3:2005/A1:2011 (pr=22554)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
2011-03-18 export to doc file  EN  FR  DE
EN 50363-4-1:2005 (pr=15054)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-4-2:2005 (pr=15055)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
2005-11-18 export to doc file  EN  FR  DE
EN 50363-5:2005 (pr=15056)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
2005-11-25 export to doc file  EN  FR  DE
EN 50363-5:2005/A1:2011 (pr=22555)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
2011-03-18 export to doc file  EN  FR  DE
EN 50363-6:2005 (pr=15057)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
2005-11-25 export to doc file  EN  FR  DE
EN 50363-6:2005/A1:2011 (pr=22556)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
2011-03-18 export to doc file  EN  FR  DE
EN 50363-7:2005 (pr=15058)
Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
2005-11-25 export to doc file  EN  FR  DE
EN 50363-8:2005 (pr=15059)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
2005-11-25 export to doc file  EN  FR  DE
EN 50363-8:2005/A1:2011 (pr=22557)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
2011-03-18 export to doc file  EN  FR  DE
EN 50363-9-1:2005 (pr=15060)
Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
2005-11-25 export to doc file  EN  FR  DE
EN 50382-1:2008 (pr=14588)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 1: General requirements
2008-03-20 export to doc file  EN  FR  DE
EN 50382-1:2008/A1:2013 (pr=24391)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 1: General requirements
2013-06-07 export to doc file  EN  FR  DE
EN 50382-2:2008 (pr=15257)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
2008-03-20 export to doc file  EN  FR  DE
EN 50382-2:2008/A1:2013 (pr=24392)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
2013-06-07 export to doc file  EN  FR  DE
EN 50393:2006 (pr=14577)
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
2006-04-06 export to doc file  EN  FR  DE
EN 50395:2005 (pr=14589)
Electrical test methods for low voltage energy cables
2005-08-19 export to doc file  EN  FR  DE
EN 50395:2005/A1:2011 (pr=22558)
Electrical test methods for low voltage energy cables
2011-03-18 export to doc file  EN  FR  DE
EN 50396:2005 (pr=14590)
Non electrical test methods for low voltage energy cables
2005-08-19 export to doc file  EN  FR
export to doc file  DE
EN 50396:2005/A1:2011 (pr=22559)
Non electrical test methods for low voltage energy cables
2011-03-18 export to doc file  EN  FR  DE
EN 50397-1:2006 (pr=13213)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors
2006-11-24 export to doc file  EN  FR  DE
EN 50397-2:2009 (pr=15157)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria
2009-10-30 export to doc file  EN  FR  DE
EN 50397-3:2010 (pr=21951)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use
2010-02-26 export to doc file  EN  FR  DE
EN 50399:2011 (pr=15313)
Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results
2011-04-15 export to doc file  EN  FR  DE
EN 50414:2006 (pr=13189)
Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining
2006-04-21 export to doc file  EN  FR  DE
EN 50483-1:2009 (pr=14573)
Test requirements for low voltage aerial bundled cable accessories - Part 1: Generalities
2009-01-30 export to doc file  EN  FR  DE
EN 50483-2:2009 (pr=284)
Test requirements for low voltage aerial bundled cable accessories - Part 2: Tension and suspension clamps for self supporting system
2009-01-30 export to doc file  EN  FR  DE
EN 50483-3:2009 (pr=285)
Test requirements for low voltage aerial bundled cable accessories - Part 3: Tension and suspension clamps for neutral messenger system
2009-01-30 export to doc file  EN  FR  DE
EN 50483-4:2009 (pr=282)
Test requirements for low voltage aerial bundled cable accessories - Part 4: Connectors
2009-01-30 export to doc file  EN  FR  DE
EN 50483-5:2009 (pr=14586)
Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test
2009-01-30 export to doc file  EN  FR  DE
EN 50483-6:2009 (pr=14585)
Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing
2009-01-30 export to doc file  EN  FR  DE
EN 50497:2007 (pr=14576)
Recommended test method for assessment of the risk of plasticizer exudation from PVC insulated and sheathed cables
2007-11-15 export to doc file  EN  FR  DE
EN 50525-1:2011 (pr=16447)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
2011-05-06 export to doc file  EN  FR  DE
EN 50525-2-11:2011 (pr=21967)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-12:2011 (pr=21968)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-21:2011 (pr=21969)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-21:2011/AC:2013 (pr=24982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
2013-08-23 export to doc file  FR
EN 50525-2-22:2011 (pr=21970)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-31:2011 (pr=21971)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-41:2011 (pr=21972)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-42:2011 (pr=21973)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-51:2011 (pr=21974)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
2011-05-06 export to doc file  EN  DE
export to doc file  FR
EN 50525-2-71:2011 (pr=21975)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
2011-05-06 export to doc file  EN  FR  DE
EN 50525-2-72:2011 (pr=21976)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
2011-05-06 export to doc file  EN  FR  DE
EN 50525-2-81:2011 (pr=21977)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
2011-05-06 export to doc file  EN  FR  DE
EN 50525-2-82:2011 (pr=21978)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
2011-05-06 export to doc file  EN  FR  DE
EN 50525-2-83:2011 (pr=21979)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
2011-05-06 export to doc file  EN  FR  DE
EN 50525-3-11:2011 (pr=21980)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
2011-05-06 export to doc file  EN  FR  DE
EN 50525-3-21:2011 (pr=21981)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
2011-05-06 export to doc file  EN  FR  DE
EN 50525-3-21:2011/AC:2013 (pr=24983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
2013-08-23 export to doc file  FR
EN 50525-3-31:2011 (pr=21982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
2011-05-06 export to doc file  EN  FR  DE
EN 50525-3-41:2011 (pr=21983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
2011-05-06 export to doc file  EN  FR  DE
EN 50565-1:2014 (pr=22562)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 1: General guidance
2014-04-04 export to doc file  EN  FR
EN 50565-2:2014 (pr=23833)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 2: Specific guidance related to EN 50525 cable types
2014-04-04 export to doc file  EN  FR
EN 60228:2005 (pr=3118)
Conductors of insulated cables
2005-02-10 export to doc file  EN  FR  DE
EN 60229:2008 (pr=21392)
Electric cables - Tests on extruded oversheaths with a special protective function
2008-06-04 export to doc file  EN  FR  DE
EN 60230:2002 (pr=14578)
Impulse tests on cables and their accessories
2002-04-10 export to doc file  EN  FR  DE
EN 60332-1-1:2004 (pr=15814)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
2004-11-15 export to doc file  EN
EN 60332-1-2:2004 (pr=15821)
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
2004-11-15 export to doc file  EN
EN 60332-1-3:2004 (pr=15823)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
2004-11-15 export to doc file  EN
EN 60332-2-1:2004 (pr=15825)
Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
2004-11-15 export to doc file  EN
EN 60332-2-2:2004 (pr=15827)
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
2004-11-15 export to doc file  EN
EN 60332-3-10:2009 (pr=16454)
Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
2009-10-07 export to doc file  EN  FR  DE
EN 60332-3-21:2009 (pr=16455)
Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
2009-10-07 export to doc file  EN  FR  DE
EN 60332-3-22:2009 (pr=16456)
Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
2009-10-07 export to doc file  EN  FR  DE
EN 60332-3-23:2009 (pr=16457)
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
2009-10-07 export to doc file  EN  FR  DE
EN 60332-3-24:2009 (pr=16458)
Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C
2009-10-07 export to doc file  EN  FR  DE
EN 60332-3-25:2009 (pr=16459)
Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D
2009-10-07 export to doc file  EN  FR  DE
EN 60702-1:2002 (pr=14005)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
2002-03-08 export to doc file  EN
EN 60702-2:2002 (pr=14006)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations
2002-03-08 export to doc file  EN
EN 60719:1993 (pr=3280)
Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
1993-08-19 export to doc file  EN
EN 60754-1:2014 (pr=24623)
Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
2014-04-18 export to doc file  EN  FR  DE
EN 60754-2:2014 (pr=24624)
Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
2014-04-18 export to doc file  EN  FR  DE
EN 60811-1-1:1995 (pr=5314)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
1995-04-05 export to doc file  EN
EN 60811-1-1:1995/A1:2001 (pr=13219)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
2001-06-08 export to doc file  EN
EN 60811-1-2:1995 (pr=5611)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
1995-04-06 export to doc file  EN
EN 60811-1-2:1995/A2:2000 (pr=6708)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
2000-12-08 export to doc file  EN
EN 60811-1-3:1995 (pr=5370)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
1995-04-06 export to doc file  EN
EN 60811-1-3:1995/A1:2001 (pr=13709)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
2001-08-02 export to doc file  EN
EN 60811-1-4:1995 (pr=5175)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
1995-04-07 export to doc file  EN
EN 60811-1-4:1995/A2:2001 (pr=13712)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
2001-10-11 export to doc file  EN
EN 60811-100:2012 (pr=22905)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
2012-06-08 export to doc file  EN  FR  DE
EN 60811-2-1:1998 (pr=11901)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
1998-08-12 export to doc file  EN
EN 60811-2-1:1998/A1:2001 (pr=13713)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
2001-10-11 export to doc file  EN
EN 60811-201:2012 (pr=22906)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness
2012-06-08 export to doc file  EN  FR  DE
EN 60811-202:2012 (pr=22907)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath
2012-06-08 export to doc file  EN  FR  DE
EN 60811-203:2012 (pr=22908)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
2012-06-08 export to doc file  EN  FR  DE
EN 60811-3-1:1995 (pr=5612)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
1995-04-10 export to doc file  EN
EN 60811-3-1:1995/A1:1996 (pr=7025)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
1996-09-16 export to doc file  EN
EN 60811-3-1:1995/A2:2001 (pr=13715)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
2001-08-02 export to doc file  EN
EN 60811-3-2:1995 (pr=5177)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
1995-04-10 export to doc file  EN
EN 60811-3-2:1995/A2:2004 (pr=15689)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
2004-03-16 export to doc file  EN
EN 60811-301:2012 (pr=22909)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 301: Electrical tests - Measurement of the permittivity at 23 °C of filling compounds
2012-06-08 export to doc file  EN  FR  DE
EN 60811-302:2012 (pr=22910)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 302: Electrical tests - Measurement of the d.c. resistivity at 23 °C and 100 °C of filling compounds
2012-06-08 export to doc file  EN  FR  DE
EN 60811-4-1:2004 (pr=15691)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
2004-08-11 export to doc file  EN
EN 60811-4-2:2004 (pr=15692)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
2004-08-11 export to doc file  EN
EN 60811-401:2012 (pr=22911)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
2012-06-15 export to doc file  EN  FR  DE
EN 60811-402:2012 (pr=22912)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests
2012-06-15 export to doc file  EN  FR  DE
EN 60811-403:2012 (pr=22913)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-404:2012 (pr=22914)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-405:2012 (pr=22915)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-406:2012 (pr=22916)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 406: Miscellaneous tests - Resistance to stress cracking of polyethylene and polypropylene compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-407:2012 (pr=22917)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 407: Miscellaneous tests - Measurement of mass increase of polyethylene and polypropylene compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-408:2012 (pr=22918)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability test of polyethylene and polypropylene compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-409:2012 (pr=22919)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-410:2012 (pr=22920)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 410: Miscellaneous tests - Test method for copper-catalyzed oxidative degradation of polyolefin insulated conductors
2012-06-15 export to doc file  EN  FR  DE
EN 60811-411:2012 (pr=22921)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 411: Miscellaneous tests - Low-temperature brittleness of filling compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-412:2012 (pr=22922)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb
2012-06-15 export to doc file  EN  FR  DE
EN 60811-5-1:1999 (pr=8087)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
1999-05-07 export to doc file  EN
EN 60811-5-1:1999/A1:2004 (pr=15693)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
2004-03-16 export to doc file  EN
EN 60811-501:2012 (pr=22923)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-502:2012 (pr=22924)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations
2012-06-15 export to doc file  EN  FR  DE
EN 60811-503:2012 (pr=22925)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-504:2012 (pr=22926)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-505:2012 (pr=22927)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-506:2012 (pr=22928)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-507:2012 (pr=22929)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
2012-06-15 export to doc file  EN  FR  DE
EN 60811-508:2012 (pr=22930)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths
2012-06-15 export to doc file  EN  FR  DE
EN 60811-509:2012 (pr=22931)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)
2012-06-15 export to doc file  EN  FR  DE
EN 60811-510:2012 (pr=22932)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air
2012-06-15 export to doc file  EN  FR  DE
EN 60811-511:2012 (pr=22933)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 511: Mechanical tests - Measurement of the melt flow index of polyethylene compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-512:2012 (pr=22934)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature
2012-06-15 export to doc file  EN  FR  DE
EN 60811-513:2012 (pr=22935)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning
2012-06-15 export to doc file  EN  FR  DE
EN 60811-601:2012 (pr=22936)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-602:2012 (pr=22937)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 602: Physical tests - Separation of oil in filling compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-603:2012 (pr=22938)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 603: Physical tests - Measurement of total acid number of filling compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-604:2012 (pr=22939)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 604: Physical tests - Measurement of absence of corrosive components in filling compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-605:2012 (pr=22940)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and/or mineral filler in polyethylene compounds
2012-06-15 export to doc file  EN  FR  DE
EN 60811-606:2012 (pr=22941)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density
2012-06-15 export to doc file  EN  FR  DE
EN 60811-607:2012 (pr=22942)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 607: Physical tests - Test for the assessment of carbon black dispersion in polyethylene and polypropylene
2012-06-15 export to doc file  EN  FR  DE
EN 60885-2:2003 (pr=3133)
Electrical test methods for electric cables - Part 2: Partial discharge tests
2003-09-30 export to doc file  EN  FR  DE
EN 60885-3:2003 (pr=15328)
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
2003-09-30 export to doc file  EN  FR  DE
EN 61034-1:2005 (pr=15843)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
2005-08-18 export to doc file  EN  FR  DE
EN 61034-1:2005/A1:2014 (pr=24012)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
2014-04-04 export to doc file  EN  FR  DE
EN 61034-2:2005 (pr=15844)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
2005-08-18 export to doc file  EN  FR  DE
EN 61034-2:2005/A1:2013 (pr=24013)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
2013-08-23 export to doc file  EN  FR  DE
EN 61138:2007 (pr=20659)
Cables for portable earthing and short-circuiting equipment
2007-12-21 export to doc file  EN  FR  DE
EN 61238-1:2003 (pr=5186)
Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements
2003-08-19 export to doc file  EN
EN 61442:2005 (pr=16045)
Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
2005-04-19 export to doc file  EN  FR  DE
EN 62230:2007 (pr=21148)
Electric cables - Spark-test method
2007-08-10 export to doc file  EN  FR  DE
EN 62230:2007/A1:2014 (pr=24616)
Electric cables - Spark-test method
2014-02-28 export to doc file  EN  FR  DE
HD 21.4 S2:1990 (pr=3184)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring
1990-12-28 export to doc file  EN
HD 21.8 S2:1999 (pr=11542)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 8: Single core non-sheathed cables for decorative chains
1999-10-06 export to doc file  EN
HD 21.9 S2:1995 (pr=4877)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
1995-02-03 export to doc file  EN
HD 21.9 S2:1995/A1:1999 (pr=11543)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
1999-10-06 export to doc file  EN
HD 361 S3:1999 (pr=3164)
System for cable designation
1999-01-19 export to doc file  EN
HD 361 S3:1999/A1:2006 (pr=15930)
System for cable designation
2006-07-28 export to doc file  EN  FR  DE
HD 516 S2:1997 (pr=3293)
Guide to use of low voltage harmonized cables
1997-11-24 export to doc file  EN
HD 516 S2:1997/A1:2003 (pr=14001)
Guide to use of low voltage harmonized cables
2003-04-30 export to doc file  EN
HD 516 S2:1997/A2:2008 (pr=21395)
Guide to use of low voltage harmonized cables
2008-10-10 export to doc file  EN  FR  DE
HD 586.3 S1:2001 (pr=13184)
Mineral insulated cables with a rated voltage not exceeding 750 V - Part 3: Guide to use
2001-07-04 export to doc file  EN
HD 603 S1:1994 (pr=3136)
Distribution cables of rated voltage 0,6/1 kV
1994-06-30 export to doc file  EN
HD 603 S1:1994/A1:1997 (pr=6704)
Distribution cables of rated voltage 0,6/1 kV
1997-12-31 export to doc file  EN
HD 603 S1:1994/A2:2003 (pr=12241)
Distribution cables of rated voltage 0,6/1 kV
2003-06-30 export to doc file  EN
HD 603 S1:1994/A3:2007 (pr=14572)
Distribution cables of rated voltage 0,6/1 kV
2007-04-06 export to doc file  EN
HD 604 S1:1994 (pr=3137)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
1994-08-19 export to doc file  EN
HD 604 S1:1994/A1:1997 (pr=6706)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
1997-03-28 export to doc file  EN
HD 604 S1:1994/A2:2002 (pr=12242)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
2002-10-04 export to doc file  EN
HD 604 S1:1994/A3:2005 (pr=15321)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
2005-10-28 export to doc file  EN
HD 605 S2:2008 (pr=14580)
Electric cables - Additional test methods
2008-07-11 export to doc file  EN  FR  DE
HD 620 S2:2010 (pr=21952)
Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV
2010-01-15 export to doc file  EN
HD 621 S1:1996 (pr=3139)
Medium voltage impregnated paper insulated distribution cables
1996-10-30 export to doc file  EN
HD 621 S1:1996/A1:2001 (pr=12964)
Medium voltage impregnated paper insulated distribution cables
2001-07-05 export to doc file  EN
HD 622 S1:1996 (pr=3141)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
1996-06-28 export to doc file  EN
HD 622 S1:1996/A1:2000 (pr=8083)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
2000-12-07 export to doc file  EN
HD 622 S1:1996/A2:2005 (pr=15322)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
2005-08-12 export to doc file  EN
HD 626 S1:1996 (pr=4817)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
1996-02-28 export to doc file  EN
HD 626 S1:1996/A1:1997 (pr=7065)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
1997-03-04 export to doc file  EN
HD 626 S1:1996/A2:2002 (pr=12965)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
2002-01-18 export to doc file  EN  FR
HD 627 S1:1996 (pr=5146)
Multicore and multipair cables for installation above and below ground
1996-10-21 export to doc file  EN
HD 627 S1:1996/A1:2000 (pr=8084)
Multicore and multipair cables for installation above and below ground
2000-12-07 export to doc file  EN
HD 627 S1:1996/A2:2005 (pr=15323)
Multicore and multipair cables for installation above and below ground
2005-11-28 export to doc file  EN
HD 629.1 S2:2006 (pr=14583)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 1: Cables with extruded insulation
2006-02-24 export to doc file  EN  FR  DE
HD 629.1 S2:2006/A1:2008 (pr=20721)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 1: Cables with extruded insulation
2008-09-10 export to doc file  EN  FR  DE
HD 629.2 S2:2006 (pr=14584)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 2: Cables with impregnated paper insulation
2006-02-24 export to doc file  EN  FR  DE
HD 629.2 S2:2006/A1:2008 (pr=20722)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 2: Cables with impregnated paper insulation
2008-09-10 export to doc file  EN  FR  DE
HD 631.1 S2:2007 (pr=13179)
Electric cables - Accessories - Material characterisation - Part 1: Fingerprinting and type tests for resinous compounds
2007-12-12 export to doc file  EN  FR  DE
HD 631.2 S1:2007 (pr=13180)
Electric cables - Accessories - Material characterisation - Part 2: Fingerprinting and type tests for heat shrinkable components for low voltage applications
2007-12-12 export to doc file  EN  FR  DE
HD 631.3 S1:2008 (pr=15326)
Electric cables - Accessories - Material characterisation - Part 3: Fingerprinting for heat shrinkable components for medium voltage applications from 3,6/6 (7,2) kV up to 20,8/36 (42) kV
2008-07-24 export to doc file  EN  FR  DE
HD 631.4 S1:2008 (pr=15327)
Electrical cables - Accessories - Material characterisation - Part 4: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV
2008-07-24 export to doc file  EN  FR  DE
HD 632 S2:2008 (pr=16460)
Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV)
2008-11-07 export to doc file  EN
HD 633 S1:1997 (pr=4932)
Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV)
1997-12-31 export to doc file  EN
HD 634 S1:1997 (pr=6672)
Tests on internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (Um = 300 kV)
1997-12-31 export to doc file  EN
HD 635 S1:1997 (pr=6673)
Tests on external gas-pressure (gas compression) cables and accessories for alternating voltages up to and including 275 kV (Um = 300 kV)
1997-12-31 export to doc file  EN

export to xls fileexport to xls file

CLC/TC 20 Maintenance cycle

 sort down
Publication number
sort upsort down
Date of Publication
Review date
sort upsort down
Result date
sort upsort down
Technical Comittee
sort upsort down
Project in progress
CLC/TR 62125:2008 (pr=21391)
Environmental statement specific to TC 20 - Electric cables
2008-04-16 2016-04-16CLC/TC 20 
EN 50143:2009 (pr=15931)
Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V
2009-03-262014-03-262017-03-26CLC/TC 20 
EN 50200:2006 (pr=15324)
Method of test for resistance to fire of unprotected small cables for use in emergency circuits
2006-05-192013-01-292016-01-29CLC/TC 20prEN 50200:2013
EN 50214:2006 (pr=11537)
Flat polyvinyl chloride sheathed flexible cables
2006-11-222011-11-222014-11-22CLC/TC 20 
EN 50262:1998 (pr=313)
Cable glands for electrical installations
1998-09-252013-02-192013-10-18CLC/TC 20EN 62444:2013
EN 50262:1998/A1:2001 (pr=11600)
Cable glands for electrical installations
2001-08-232013-02-192013-10-18CLC/TC 20EN 62444:2013
EN 50262:1998/A2:2004 (pr=14575)
Cable glands for electrical installations
2004-12-142013-02-192013-10-18CLC/TC 20EN 62444:2013
EN 50264-1:2008 (pr=14587)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
2008-06-272013-06-272016-06-27CLC/TC 20 
EN 50264-2-1:2008 (pr=15251)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
2008-06-272013-06-272016-06-27CLC/TC 20 
EN 50264-2-2:2008 (pr=15252)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
2008-06-272013-06-272016-06-27CLC/TC 20 
EN 50264-3-1:2008 (pr=15253)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
2008-06-272013-06-272016-06-27CLC/TC 20 
EN 50264-3-2:2008 (pr=15254)
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
2008-06-272013-06-272016-06-27CLC/TC 20 
EN 50267-1:1998 (pr=5256)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
1998-06-172013-01-292014-04-18CLC/TC 20EN 60754-1:2014
EN 50267-2-1:1998 (pr=6701)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
1998-06-172013-01-292014-04-18CLC/TC 20EN 60754-1:2014
EN 50267-2-2:1998 (pr=7132)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
1998-06-172013-01-292014-04-18CLC/TC 20EN 60754-1:2014
EN 50267-2-3:1998 (pr=7133)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
1998-06-172013-01-292014-04-18CLC/TC 20EN 60754-1:2014
EN 50305:2002 (pr=7064)
Railway applications - Railway rolling stock cables having special fire performance - Test methods
2002-07-192007-07-192010-07-19CLC/TC 20 
EN 50306-1:2002 (pr=11548)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
2002-10-302007-10-302010-10-30CLC/TC 20 
EN 50306-2:2002 (pr=11549)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
2002-10-302007-10-302010-10-30CLC/TC 20 
EN 50306-3:2002 (pr=11550)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
2002-10-312007-10-312010-10-31CLC/TC 20 
EN 50306-4:2002 (pr=11551)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
2002-10-312007-10-312010-10-31CLC/TC 20 
EN 50307:2002 (pr=7325)
Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables
2002-12-102007-12-102010-12-10CLC/TC 20 
EN 50334:2001 (pr=13166)
Marking by inscription for the identification of cores of electric cables
2001-04-122006-04-122009-04-12CLC/TC 20 
EN 50355:2003 (pr=7063)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use
2003-09-262012-09-182013-08-30CLC/TC 20EN 50355:2013
EN 50355:2013 (pr=24390)
Railway applications - Railway rolling stock cables having special fire performance - Guide to use
2013-08-302018-08-302021-08-30CLC/TC 20 
EN 50362:2003 (pr=14003)
Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits
2003-02-072008-02-072011-02-07CLC/TC 20 
EN 50363-0:2011 (pr=22552)
Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-10-1:2005 (pr=15061)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-10-2:2005 (pr=15062)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-1:2005 (pr=15050)
Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-2-1:2005 (pr=15051)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-2-1:2005/A1:2011 (pr=22553)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-2-2:2005 (pr=15052)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-3:2005 (pr=15053)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-3:2005/A1:2011 (pr=22554)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-4-1:2005 (pr=15054)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-4-2:2005 (pr=15055)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
2005-11-182010-11-182013-11-18CLC/TC 20 
EN 50363-5:2005 (pr=15056)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-5:2005/A1:2011 (pr=22555)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-6:2005 (pr=15057)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-6:2005/A1:2011 (pr=22556)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-7:2005 (pr=15058)
Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-8:2005 (pr=15059)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50363-8:2005/A1:2011 (pr=22557)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50363-9-1:2005 (pr=15060)
Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
2005-11-252010-11-252013-11-25CLC/TC 20 
EN 50382-1:2008 (pr=14588)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 1: General requirements
2008-03-202013-03-202016-03-20CLC/TC 20 
EN 50382-1:2008/A1:2013 (pr=24391)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 1: General requirements
2013-06-072018-06-072021-06-07CLC/TC 20 
EN 50382-2:2008 (pr=15257)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
2008-03-202013-03-202016-03-20CLC/TC 20 
EN 50382-2:2008/A1:2013 (pr=24392)
Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 2: Single core silicone rubber insulated cables for 120 °C or 150 °C
2013-06-072018-06-072021-06-07CLC/TC 20 
EN 50393:2006 (pr=14577)
Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV
2006-04-062011-06-012014-06-01CLC/TC 20prEN 50393:2012
EN 50395:2005 (pr=14589)
Electrical test methods for low voltage energy cables
2005-08-192010-08-192013-08-19CLC/TC 20 
EN 50395:2005/A1:2011 (pr=22558)
Electrical test methods for low voltage energy cables
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50396:2005 (pr=14590)
Non electrical test methods for low voltage energy cables
2005-08-192010-08-192013-08-19CLC/TC 20 
EN 50396:2005/A1:2011 (pr=22559)
Non electrical test methods for low voltage energy cables
2011-03-182016-03-182019-03-18CLC/TC 20 
EN 50397-1:2006 (pr=13213)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 1: Covered conductors
2006-11-242011-11-242014-11-24CLC/TC 20 
EN 50397-2:2009 (pr=15157)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV AC and not exceeding 36 kV AC - Part 2: Accessories for covered conductors - Tests and acceptance criteria
2009-10-302014-10-302017-10-30CLC/TC 20 
EN 50397-3:2010 (pr=21951)
Covered conductors for overhead lines and the related accessories for rated voltages above 1 kV a.c. and not exceeding 36 kV a.c. - Part 3: Guide to use
2010-02-262015-02-262018-02-26CLC/TC 20 
EN 50399:2011 (pr=15313)
Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test apparatus, procedures, results
2011-04-152016-04-152019-04-15CLC/TC 20 
EN 50414:2006 (pr=13189)
Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining
2006-04-212011-04-212014-04-21CLC/TC 20 
EN 50483-1:2009 (pr=14573)
Test requirements for low voltage aerial bundled cable accessories - Part 1: Generalities
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50483-2:2009 (pr=284)
Test requirements for low voltage aerial bundled cable accessories - Part 2: Tension and suspension clamps for self supporting system
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50483-3:2009 (pr=285)
Test requirements for low voltage aerial bundled cable accessories - Part 3: Tension and suspension clamps for neutral messenger system
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50483-4:2009 (pr=282)
Test requirements for low voltage aerial bundled cable accessories - Part 4: Connectors
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50483-5:2009 (pr=14586)
Test requirements for low voltage aerial bundled cable accessories - Part 5: Electrical ageing test
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50483-6:2009 (pr=14585)
Test requirements for low voltage aerial bundled cable accessories - Part 6: Environmental testing
2009-01-302014-01-302017-01-30CLC/TC 20 
EN 50497:2007 (pr=14576)
Recommended test method for assessment of the risk of plasticizer exudation from PVC insulated and sheathed cables
2007-11-152012-11-152015-11-15CLC/TC 20 
EN 50525-1:2011 (pr=16447)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-11:2011 (pr=21967)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-12:2011 (pr=21968)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-21:2011 (pr=21969)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-21:2011/AC:2013 (pr=24982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
2013-08-232018-08-232021-08-23CLC/TC 20 
EN 50525-2-22:2011 (pr=21970)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-31:2011 (pr=21971)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-41:2011 (pr=21972)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-42:2011 (pr=21973)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-51:2011 (pr=21974)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-71:2011 (pr=21975)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-72:2011 (pr=21976)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-81:2011 (pr=21977)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-82:2011 (pr=21978)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-2-83:2011 (pr=21979)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-3-11:2011 (pr=21980)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-3-21:2011 (pr=21981)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-3-21:2011/AC:2013 (pr=24983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
2013-08-232018-08-232021-08-23CLC/TC 20 
EN 50525-3-31:2011 (pr=21982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50525-3-41:2011 (pr=21983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
2011-05-062016-05-062019-05-06CLC/TC 20 
EN 50565-1:2014 (pr=22562)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 1: General guidance
2014-04-042019-04-042022-04-04CLC/TC 20 
EN 50565-2:2014 (pr=23833)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 2: Specific guidance related to EN 50525 cable types
2014-04-042019-04-042022-04-04CLC/TC 20 
EN 60228:2005 (pr=3118)
Conductors of insulated cables
2005-02-10 2013-02-10CLC/TC 20 
EN 60229:2008 (pr=21392)
Electric cables - Tests on extruded oversheaths with a special protective function
2008-06-04 2016-06-04CLC/TC 20 
EN 60230:2002 (pr=14578)
Impulse tests on cables and their accessories
2002-04-10 2010-04-10CLC/TC 20 
EN 60332-1-1:2004 (pr=15814)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
2004-11-15 2012-11-15CLC/TC 20 
EN 60332-1-2:2004 (pr=15821)
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
2004-11-15 2012-11-15CLC/TC 20 
EN 60332-1-3:2004 (pr=15823)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
2004-11-15 2012-11-15CLC/TC 20 
EN 60332-2-1:2004 (pr=15825)
Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
2004-11-15 2012-11-15CLC/TC 20 
EN 60332-2-2:2004 (pr=15827)
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
2004-11-15 2012-11-15CLC/TC 20 
EN 60332-3-10:2009 (pr=16454)
Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
2009-10-07 2017-10-07CLC/TC 20 
EN 60332-3-21:2009 (pr=16455)
Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
2009-10-07 2017-10-07CLC/TC 20 
EN 60332-3-22:2009 (pr=16456)
Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
2009-10-07 2017-10-07CLC/TC 20 
EN 60332-3-23:2009 (pr=16457)
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
2009-10-07 2017-10-07CLC/TC 20 
EN 60332-3-24:2009 (pr=16458)
Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C
2009-10-07 2017-10-07CLC/TC 20 
EN 60332-3-25:2009 (pr=16459)
Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D
2009-10-07 2017-10-07CLC/TC 20 
EN 60702-1:2002 (pr=14005)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
2002-03-08 2010-03-08CLC/TC 20 
EN 60702-2:2002 (pr=14006)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations
2002-03-08 2010-03-08CLC/TC 20 
EN 60719:1993 (pr=3280)
Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
1993-08-19 2001-08-19CLC/TC 20 
EN 60754-1:2014 (pr=24623)
Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
2014-04-18 2022-04-18CLC/TC 20 
EN 60754-2:2014 (pr=24624)
Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
2014-04-18 2022-04-18CLC/TC 20 
EN 60811-1-1:1995 (pr=5314)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
1995-04-05 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-1:1995/A1:2001 (pr=13219)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
2001-06-08 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-2:1995 (pr=5611)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
1995-04-06 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-2:1995/A2:2000 (pr=6708)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
2000-12-08 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-3:1995 (pr=5370)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
1995-04-06 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-3:1995/A1:2001 (pr=13709)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
2001-08-02 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-4:1995 (pr=5175)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
1995-04-07 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-1-4:1995/A2:2001 (pr=13712)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
2001-10-11 2012-06-15CLC/TC 20EN 60811-504:2012
EN 60811-100:2012 (pr=22905)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-2-1:1998 (pr=11901)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
1998-08-12 2012-06-08CLC/TC 20EN 60811-100:2012
EN 60811-2-1:1998/A1:2001 (pr=13713)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
2001-10-11 2012-06-15CLC/TC 20EN 60811-507:2012
EN 60811-201:2012 (pr=22906)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-202:2012 (pr=22907)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-203:2012 (pr=22908)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-3-1:1995 (pr=5612)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
1995-04-10 2012-06-15CLC/TC 20EN 60811-508:2012
EN 60811-3-1:1995/A1:1996 (pr=7025)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
1996-09-16 2012-06-15CLC/TC 20EN 60811-508:2012
EN 60811-3-1:1995/A2:2001 (pr=13715)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
2001-08-02 2012-06-15CLC/TC 20EN 60811-508:2012
EN 60811-3-2:1995 (pr=5177)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
1995-04-10 2012-06-15CLC/TC 20EN 60811-405:2012
EN 60811-3-2:1995/A2:2004 (pr=15689)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
2004-03-16 2012-06-15CLC/TC 20EN 60811-405:2012
EN 60811-301:2012 (pr=22909)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 301: Electrical tests - Measurement of the permittivity at 23 °C of filling compounds
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-302:2012 (pr=22910)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 302: Electrical tests - Measurement of the d.c. resistivity at 23 °C and 100 °C of filling compounds
2012-06-08 2020-06-08CLC/TC 20 
EN 60811-4-1:2004 (pr=15691)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
2004-08-11 2012-06-15CLC/TC 20EN 60811-406:2012
EN 60811-4-2:2004 (pr=15692)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
2004-08-11 2012-06-15CLC/TC 20EN 60811-407:2012
EN 60811-401:2012 (pr=22911)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-402:2012 (pr=22912)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-403:2012 (pr=22913)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-404:2012 (pr=22914)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-405:2012 (pr=22915)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-406:2012 (pr=22916)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 406: Miscellaneous tests - Resistance to stress cracking of polyethylene and polypropylene compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-407:2012 (pr=22917)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 407: Miscellaneous tests - Measurement of mass increase of polyethylene and polypropylene compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-408:2012 (pr=22918)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability test of polyethylene and polypropylene compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-409:2012 (pr=22919)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-410:2012 (pr=22920)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 410: Miscellaneous tests - Test method for copper-catalyzed oxidative degradation of polyolefin insulated conductors
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-411:2012 (pr=22921)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 411: Miscellaneous tests - Low-temperature brittleness of filling compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-412:2012 (pr=22922)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-5-1:1999 (pr=8087)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
1999-05-07 2012-06-08CLC/TC 20EN 60811-301:2012
EN 60811-5-1:1999/A1:2004 (pr=15693)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
2004-03-16 2012-06-08CLC/TC 20EN 60811-301:2012
EN 60811-501:2012 (pr=22923)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-502:2012 (pr=22924)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-503:2012 (pr=22925)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-504:2012 (pr=22926)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-505:2012 (pr=22927)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-506:2012 (pr=22928)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-507:2012 (pr=22929)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-508:2012 (pr=22930)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-509:2012 (pr=22931)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-510:2012 (pr=22932)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-511:2012 (pr=22933)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 511: Mechanical tests - Measurement of the melt flow index of polyethylene compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-512:2012 (pr=22934)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-513:2012 (pr=22935)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-601:2012 (pr=22936)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-602:2012 (pr=22937)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 602: Physical tests - Separation of oil in filling compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-603:2012 (pr=22938)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 603: Physical tests - Measurement of total acid number of filling compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-604:2012 (pr=22939)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 604: Physical tests - Measurement of absence of corrosive components in filling compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-605:2012 (pr=22940)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and/or mineral filler in polyethylene compounds
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-606:2012 (pr=22941)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density
2012-06-15 2020-06-15CLC/TC 20 
EN 60811-607:2012 (pr=22942)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 607: Physical tests - Test for the assessment of carbon black dispersion in polyethylene and polypropylene
2012-06-15 2020-06-15CLC/TC 20 
EN 60885-2:2003 (pr=3133)
Electrical test methods for electric cables - Part 2: Partial discharge tests
2003-09-30 2011-09-30CLC/TC 20 
EN 60885-3:2003 (pr=15328)
Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
2003-09-30 2016-10-01CLC/TC 20FprEN 60885-3:2013
EN 61034-1:2005 (pr=15843)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
2005-08-18 2013-08-18CLC/TC 20 
EN 61034-1:2005/A1:2014 (pr=24012)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
2014-04-04 2022-04-04CLC/TC 20 
EN 61034-2:2005 (pr=15844)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
2005-08-18 2013-08-18CLC/TC 20 
EN 61034-2:2005/A1:2013 (pr=24013)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
2013-08-23 2021-08-23CLC/TC 20 
EN 61138:2007 (pr=20659)
Cables for portable earthing and short-circuiting equipment
2007-12-21 2015-12-21CLC/TC 20 
EN 61238-1:2003 (pr=5186)
Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements
2003-08-19 2011-08-19CLC/TC 20 
EN 61442:2005 (pr=16045)
Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
2005-04-19 2013-04-19CLC/TC 20 
EN 62230:2007 (pr=21148)
Electric cables - Spark-test method
2007-08-10 2015-08-10CLC/TC 20 
EN 62230:2007/A1:2014 (pr=24616)
Electric cables - Spark-test method
2014-02-28 2022-02-28CLC/TC 20 
HD 21.4 S2:1990 (pr=3184)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring
1990-12-28 1998-12-28CLC/TC 20 
HD 21.8 S2:1999 (pr=11542)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 8: Single core non-sheathed cables for decorative chains
1999-10-062004-10-062007-10-06CLC/TC 20 
HD 21.9 S2:1995 (pr=4877)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
1995-02-032000-02-032003-02-03CLC/TC 20 
HD 21.9 S2:1995/A1:1999 (pr=11543)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
1999-10-062004-10-062007-10-06CLC/TC 20 
HD 361 S3:1999 (pr=3164)
System for cable designation
1999-01-192004-01-192007-01-19CLC/TC 20 
HD 361 S3:1999/A1:2006 (pr=15930)
System for cable designation
2006-07-282011-07-282014-07-28CLC/TC 20 
HD 516 S2:1997 (pr=3293)
Guide to use of low voltage harmonized cables
1997-11-242011-05-012014-04-04CLC/TC 20EN 50565-1:2014
HD 516 S2:1997/A1:2003 (pr=14001)
Guide to use of low voltage harmonized cables
2003-04-302011-05-012014-04-04CLC/TC 20EN 50565-1:2014
HD 516 S2:1997/A2:2008 (pr=21395)
Guide to use of low voltage harmonized cables
2008-10-102011-05-012014-04-04CLC/TC 20EN 50565-1:2014
HD 586.3 S1:2001 (pr=13184)
Mineral insulated cables with a rated voltage not exceeding 750 V - Part 3: Guide to use
2001-07-042006-07-042009-07-04CLC/TC 20 
HD 603 S1:1994 (pr=3136)
Distribution cables of rated voltage 0,6/1 kV
1994-06-302009-10-012012-10-01CLC/TC 20HD 603 S2:201X
HD 603 S1:1994/A1:1997 (pr=6704)
Distribution cables of rated voltage 0,6/1 kV
1997-12-312009-10-012012-10-01CLC/TC 20HD 603 S2:201X
HD 603 S1:1994/A2:2003 (pr=12241)
Distribution cables of rated voltage 0,6/1 kV
2003-06-302009-10-012012-10-01CLC/TC 20HD 603 S2:201X
HD 603 S1:1994/A3:2007 (pr=14572)
Distribution cables of rated voltage 0,6/1 kV
2007-04-062009-10-012012-10-01CLC/TC 20HD 603 S2:201X
HD 604 S1:1994 (pr=3137)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
1994-08-191999-08-192002-08-19CLC/TC 20 
HD 604 S1:1994/A1:1997 (pr=6706)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
1997-03-282002-03-282005-03-28CLC/TC 20 
HD 604 S1:1994/A2:2002 (pr=12242)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
2002-10-042007-10-042010-10-04CLC/TC 20 
HD 604 S1:1994/A3:2005 (pr=15321)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
2005-10-282010-10-282013-10-28CLC/TC 20 
HD 605 S2:2008 (pr=14580)
Electric cables - Additional test methods
2008-07-112013-07-112016-07-11CLC/TC 20 
HD 620 S2:2010 (pr=21952)
Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV
2010-01-152015-01-152018-01-15CLC/TC 20 
HD 621 S1:1996 (pr=3139)
Medium voltage impregnated paper insulated distribution cables
1996-10-302001-10-302004-10-30CLC/TC 20 
HD 621 S1:1996/A1:2001 (pr=12964)
Medium voltage impregnated paper insulated distribution cables
2001-07-052006-07-052009-07-05CLC/TC 20 
HD 622 S1:1996 (pr=3141)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
1996-06-282001-06-282004-06-28CLC/TC 20 
HD 622 S1:1996/A1:2000 (pr=8083)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
2000-12-072005-12-072008-12-07CLC/TC 20 
HD 622 S1:1996/A2:2005 (pr=15322)
Power cables having rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV with special fire performance for use in power stations
2005-08-122010-08-122013-08-12CLC/TC 20 
HD 626 S1:1996 (pr=4817)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
1996-02-282001-02-282004-02-28CLC/TC 20 
HD 626 S1:1996/A1:1997 (pr=7065)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
1997-03-042002-03-042005-03-04CLC/TC 20 
HD 626 S1:1996/A2:2002 (pr=12965)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
2002-01-182007-01-182010-01-18CLC/TC 20 
HD 627 S1:1996 (pr=5146)
Multicore and multipair cables for installation above and below ground
1996-10-212001-10-212004-10-21CLC/TC 20 
HD 627 S1:1996/A1:2000 (pr=8084)
Multicore and multipair cables for installation above and below ground
2000-12-072005-12-072008-12-07CLC/TC 20 
HD 627 S1:1996/A2:2005 (pr=15323)
Multicore and multipair cables for installation above and below ground
2005-11-282010-11-282013-11-28CLC/TC 20 
HD 629.1 S2:2006 (pr=14583)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 1: Cables with extruded insulation
2006-02-242011-02-242014-02-24CLC/TC 20 
HD 629.1 S2:2006/A1:2008 (pr=20721)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 1: Cables with extruded insulation
2008-09-102013-09-102016-09-10CLC/TC 20 
HD 629.2 S2:2006 (pr=14584)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 2: Cables with impregnated paper insulation
2006-02-242011-02-242014-02-24CLC/TC 20 
HD 629.2 S2:2006/A1:2008 (pr=20722)
Test requirements on accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV - Part 2: Cables with impregnated paper insulation
2008-09-102013-09-102016-09-10CLC/TC 20 
HD 631.1 S2:2007 (pr=13179)
Electric cables - Accessories - Material characterisation - Part 1: Fingerprinting and type tests for resinous compounds
2007-12-122012-12-122015-12-12CLC/TC 20 
HD 631.2 S1:2007 (pr=13180)
Electric cables - Accessories - Material characterisation - Part 2: Fingerprinting and type tests for heat shrinkable components for low voltage applications
2007-12-122012-12-122015-12-12CLC/TC 20 
HD 631.3 S1:2008 (pr=15326)
Electric cables - Accessories - Material characterisation - Part 3: Fingerprinting for heat shrinkable components for medium voltage applications from 3,6/6 (7,2) kV up to 20,8/36 (42) kV
2008-07-242013-07-242016-07-24CLC/TC 20 
HD 631.4 S1:2008 (pr=15327)
Electrical cables - Accessories - Material characterisation - Part 4: Fingerprinting for cold shrinkable components for low and medium voltage applications up to 20,8/36 (42) kV
2008-07-242013-07-242016-07-24CLC/TC 20 
HD 632 S2:2008 (pr=16460)
Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV)
2008-11-072009-10-012012-10-01CLC/TC 20HD 632 S3:201X
HD 633 S1:1997 (pr=4932)
Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV)
1997-12-312002-12-312005-12-31CLC/TC 20 
HD 634 S1:1997 (pr=6672)
Tests on internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (Um = 300 kV)
1997-12-312002-12-312005-12-31CLC/TC 20 
HD 635 S1:1997 (pr=6673)
Tests on external gas-pressure (gas compression) cables and accessories for alternating voltages up to and including 275 kV (Um = 300 kV)
1997-12-312002-12-312005-12-31CLC/TC 20 

export to xls file

TC 3 Project files


CLC/TC 20 TC/SC in figures

Current Stage
Year
Year -1
Year -2
Year -3
Year -4
Year >5
Proposal stage000010
Enquiry stage411000
Approval stage520000
Published6638272139
Withdrawn00000266
Approved020000

CLC/TC 20 Figures overall

Total publications
32
Published in last 3 years
7
Total work in progress
15
Total proposals
0
export to xls file

CLC/TC 20 Environment

Reference
Clause
Categories - Aspects
Product Life Cycle
Information
Confirmed
EN 50414:2006 (pr=13189)
Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining
All Hazardous substances Manufacturing B2B Y
CLC/TR 62125:2008 (pr=21391)
Environmental statement specific to TC 20 - Electric cables
4 & Annexes Energy use Raw Material, Manufacturing, Use, Recovery, Disposal B2B, DfE N
4 & Annexes Hazardous substances Raw Material, Manufacturing, Use, Recovery, Disposal B2B, DfE
4 & Annexes Waste Raw Material, Manufacturing, Use, Recovery, Disposal B2B, DfE

export to xls file

CLC/TC 20 EU Directive(s)

Reference
Stage code
Directive
OJ Status
OJ Reference
Mandate
HD 21.4 S2:1990 (pr=3184)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 21.8 S2:1999 (pr=11542)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 8: Single core non-sheathed cables for decorative chains
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 21.9 S2:1995 (pr=4877)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 21.9 S2:1995/A1:1999 (pr=11543)
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 9: Single core non-sheathed cable for installation at low temperatures
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 361 S3:1999 (pr=3164)
System for cable designation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 361 S3:1999/A1:2006 (pr=15930)
System for cable designation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 516 S2:1997 (pr=3293)
Guide to use of low voltage harmonized cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 516 S2:1997/A1:2003 (pr=14001)
Guide to use of low voltage harmonized cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 516 S2:1997/A2:2008 (pr=21395)
Guide to use of low voltage harmonized cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 603 S1:1994 (pr=3136)
Distribution cables of rated voltage 0,6/1 kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 603 S1:1994/A1:1997 (pr=6704)
Distribution cables of rated voltage 0,6/1 kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 603 S1:1994/A2:2003 (pr=12241)
Distribution cables of rated voltage 0,6/1 kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 603 S1:1994/A3:2007 (pr=14572)
Distribution cables of rated voltage 0,6/1 kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 603 S2:201X (pr=22561)
Distribution cables of rated voltage 0,6/1 kV
5099 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
HD 604 S1:1994 (pr=3137)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 604 S1:1994/A1:1997 (pr=6706)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 604 S1:1994/A2:2002 (pr=12242)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 604 S1:1994/A3:2005 (pr=15321)
0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 605 S2:2008 (pr=14580)
Electric cables - Additional test methods
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 626 S1:1996 (pr=4817)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 626 S1:1996/A1:1997 (pr=7065)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 626 S1:1996/A2:2002 (pr=12965)
Overhead distribution cables of rated voltage Uo/U(Um): 0,6/1 (1,2) kV
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 627 S1:1996 (pr=5146)
Multicore and multipair cables for installation above and below ground
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 627 S1:1996/A1:2000 (pr=8084)
Multicore and multipair cables for installation above and below ground
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
HD 627 S1:1996/A2:2005 (pr=15323)
Multicore and multipair cables for installation above and below ground
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50214:2006 (pr=11537)
Flat polyvinyl chloride sheathed flexible cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50262:1998 (pr=313)
Cable glands for electrical installations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50262:1998/A1:2001 (pr=11600)
Cable glands for electrical installations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50262:1998/A2:2004 (pr=14575)
Cable glands for electrical installations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50267-1:1998 (pr=5256)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50267-2-1:1998 (pr=6701)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50267-2-2:1998 (pr=7132)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50267-2-3:1998 (pr=7133)
Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50355:2003 (pr=7063)
Railway applications - Railway rolling stock cables having special fire performance - Thin wall and standard wall - Guide to use
6060 2001/16/EC
Directive 2001/16/EC of the European Parliament and of the Council of 19 March 2001 on the interoperability of the trans-European conventional rail system
LEG
EN 50363-0:2011 (pr=22552)
Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-1:2005 (pr=15050)
Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-2-1:2005 (pr=15051)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-2-1:2005/A1:2011 (pr=22553)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-1: Cross-linked elastomeric sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-2-2:2005 (pr=15052)
Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-3:2005 (pr=15053)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-3:2005/A1:2011 (pr=22554)
Insulating, sheathing and covering materials for low voltage energy cables - Part 3: PVC insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-4-1:2005 (pr=15054)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-4-2:2005 (pr=15055)
Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-5:2005 (pr=15056)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-5:2005/A1:2011 (pr=22555)
Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-6:2005 (pr=15057)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-6:2005/A1:2011 (pr=22556)
Insulating, sheathing and covering materials for low voltage energy cables - Part 6: Halogen-free, cross-linked sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-7:2005 (pr=15058)
Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-8:2005 (pr=15059)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-8:2005/A1:2011 (pr=22557)
Insulating, sheathing and covering materials for low voltage energy cables - Part 8: Halogen-free, thermoplastic sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-9-1:2005 (pr=15060)
Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-10-1:2005 (pr=15061)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50363-10-2:2005 (pr=15062)
Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50395:2005 (pr=14589)
Electrical test methods for low voltage energy cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50395:2005/A1:2011 (pr=22558)
Electrical test methods for low voltage energy cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50396:2005 (pr=14590)
Non electrical test methods for low voltage energy cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50396:2005/A1:2011 (pr=22559)
Non electrical test methods for low voltage energy cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50497:2007 (pr=14576)
Recommended test method for assessment of the risk of plasticizer exudation from PVC insulated and sheathed cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-1:2011 (pr=16447)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-11:2011 (pr=21967)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-12:2011 (pr=21968)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-21:2011 (pr=21969)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-21:2011/AC:2013 (pr=24982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-21: Cables for general applications - Flexible cables with crosslinked elastomeric insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 50525-2-22:2011 (pr=21970)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-31:2011 (pr=21971)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-41:2011 (pr=21972)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-42:2011 (pr=21973)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-51:2011 (pr=21974)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-71:2011 (pr=21975)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-72:2011 (pr=21976)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-81:2011 (pr=21977)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-82:2011 (pr=21978)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-2-83:2011 (pr=21979)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-3-11:2011 (pr=21980)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-3-21:2011 (pr=21981)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-3-21:2011/AC:2013 (pr=24983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 50525-3-31:2011 (pr=21982)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50525-3-41:2011 (pr=21983)
Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 50565-1:2014 (pr=22562)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 1: General guidance
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 50565-2:2014 (pr=23833)
Electric cables - Guide to use for cables with a rated voltage not exceeding 450/750 V (U0/U) - Part 2: Specific guidance related to EN 50525 cable types
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
FprEN 50575:2014 (pr=23570)
Power, control and communication cables - Cables for general applications in construction works subject to reaction to fire requirements
4099 89/106/EEC
Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products
NEW
CLC/FprTS 50576:2014 (pr=24625)
Electric cables - Extended application of test results
5020 89/106/EEC
Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products
NEW
prEN 50618:2013 (pr=24019)
Electric cables for photovoltaic systems
4060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60228:2005 (pr=3118)
Conductors of insulated cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-1-1:2004 (pr=15814)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-1-1:2004/FprA1:2014 (pr=25349)
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
5020 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60332-1-2:2004 (pr=15821)
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-1-2:2004/FprA1:2014 (pr=25350)
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
5020 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60332-1-3:2004 (pr=15823)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-1-3:2004/FprA1:2014 (pr=25351)
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
5020 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60332-2-1:2004 (pr=15825)
Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-2-2:2004 (pr=15827)
Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-10:2009 (pr=16454)
Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-21:2009 (pr=16455)
Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-22:2009 (pr=16456)
Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-23:2009 (pr=16457)
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-24:2009 (pr=16458)
Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60332-3-25:2009 (pr=16459)
Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60702-1:2002 (pr=14005)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60702-1:2002/FprA1:2013 (pr=24586)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables
5060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60702-2:2002 (pr=14006)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60702-2:2002/FprA1:2013 (pr=24587)
Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 2: Terminations
5060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60719:1993 (pr=3280)
Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60754-1:2014 (pr=24623)
Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60754-2:2014 (pr=24624)
Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 60811-1-1:1995 (pr=5314)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-1:1995/A1:2001 (pr=13219)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-1: General application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-2:1995 (pr=5611)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-2:1995/A2:2000 (pr=6708)
Insulating and sheathing materials of electric cables - Common test methods - Part 1-2: General application - Thermal ageing methods
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-3:1995 (pr=5370)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-3:1995/A1:2001 (pr=13709)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-3: General application - Methods for determining the density - Water absorption tests - Shrinkage test
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-4:1995 (pr=5175)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-1-4:1995/A2:2001 (pr=13712)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperature
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-2-1:1998 (pr=11901)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-2-1:1998/A1:2001 (pr=13713)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-3-1:1995 (pr=5612)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-3-1:1995/A1:1996 (pr=7025)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-3-1:1995/A2:2001 (pr=13715)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-3-2:1995 (pr=5177)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-3-2:1995/A2:2004 (pr=15689)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 3-2: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-4-1:2004 (pr=15691)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-1: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black and/or mineral filler content measurement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-4-2:2004 (pr=15692)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Wrapping test after conditioning at elevated temperature - Wrapping test after thermal ageing in air - Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-5-1:1999 (pr=8087)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-5-1:1999/A1:2004 (pr=15693)
Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - D.C. resistivity at 23 °C and 100 °C
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-100:2012 (pr=22905)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-201:2012 (pr=22906)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-202:2012 (pr=22907)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-203:2012 (pr=22908)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-301:2012 (pr=22909)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 301: Electrical tests - Measurement of the permittivity at 23 °C of filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-302:2012 (pr=22910)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 302: Electrical tests - Measurement of the d.c. resistivity at 23 °C and 100 °C of filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-401:2012 (pr=22911)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-402:2012 (pr=22912)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-403:2012 (pr=22913)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-404:2012 (pr=22914)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-405:2012 (pr=22915)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-406:2012 (pr=22916)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 406: Miscellaneous tests - Resistance to stress cracking of polyethylene and polypropylene compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-407:2012 (pr=22917)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 407: Miscellaneous tests - Measurement of mass increase of polyethylene and polypropylene compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-408:2012 (pr=22918)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 408: Miscellaneous tests - Long-term stability test of polyethylene and polypropylene compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-409:2012 (pr=22919)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-410:2012 (pr=22920)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 410: Miscellaneous tests - Test method for copper-catalyzed oxidative degradation of polyolefin insulated conductors
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-411:2012 (pr=22921)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 411: Miscellaneous tests - Low-temperature brittleness of filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-412:2012 (pr=22922)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 412: Miscellaneous tests - Thermal ageing methods - Ageing in an air bomb
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-501:2012 (pr=22923)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-502:2012 (pr=22924)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-503:2012 (pr=22925)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-504:2012 (pr=22926)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-505:2012 (pr=22927)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-506:2012 (pr=22928)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-507:2012 (pr=22929)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-508:2012 (pr=22930)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-509:2012 (pr=22931)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-510:2012 (pr=22932)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-511:2012 (pr=22933)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 511: Mechanical tests - Measurement of the melt flow index of polyethylene compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-512:2012 (pr=22934)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-513:2012 (pr=22935)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-601:2012 (pr=22936)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 601: Physical tests - Measurement of the drop point of filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-602:2012 (pr=22937)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 602: Physical tests - Separation of oil in filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-603:2012 (pr=22938)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 603: Physical tests - Measurement of total acid number of filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-604:2012 (pr=22939)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 604: Physical tests - Measurement of absence of corrosive components in filling compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-605:2012 (pr=22940)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and/or mineral filler in polyethylene compounds
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-606:2012 (pr=22941)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 60811-607:2012 (pr=22942)
Electric and optical fibre cables - Test methods for non-metallic materials - Part 607: Physical tests - Test for the assessment of carbon black dispersion in polyethylene and polypropylene
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 61034-1:2005 (pr=15843)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 61034-1:2005/A1:2014 (pr=24012)
Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NEW
EN 61034-2:2005 (pr=15844)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 61034-2:2005/A1:2013 (pr=24013)
Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03
EN 61138:2007 (pr=20659)
Cables for portable earthing and short-circuiting equipment
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
PUB C 348/03