CLC/TC 14

Power transformers

 
export to xls file

CLC/TC 14 Work programme

sort up 
Project reference
sort upsort down
Current Code
sort upsort down
Document
Init. Date
sort upsort down
Current stage
sort upsort down
Next Stage
sort upsort down
Fcst. voting date
prEN 50216-4:2013 (pr=22810)
Power transformer and reactor fittings - Part 4: Basic accessories (earthing terminal, drain and filling devices, thermometer pocket, wheel assembly)
4060 2010-01-182014-01-062014-01-27 
prEN 50299-1:2013 (pr=24705)
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
4090 2013-01-242014-04-03  
prEN 50299-2:2013 (pr=24706)
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
4090 2013-01-242014-04-03  
FprEN 50588-1:201X (pr=24468)
Medium voltage transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
4092  2012-10-012014-02-18  
FprEN 50629:201X (pr=25005)
Energy efficiency of transformers with Um greater than 36 kV
4092  2013-08-122014-02-18  
FprEN 60076-10:2013 (pr=25043)
Power transformers - Part 10: Determination of sound levels
5060  2013-09-032014-02-172014-03-10 
FprEN 60214-1:2013 (pr=24779)
Tap-changers - Part 1: Performance requirements and test methods
5060  2013-03-042013-08-192013-09-09 

export to xls file

CLC/TC 14 Publications

Reference, Title
sort up  
Publication date
Downloads
CLC/TR 50453:2007 (pr=16657)
Evaluation of electromagnetic fields around power transformers
2007-05-16 export to doc file  EN
export to doc file  FR
CLC/TR 50462:2008 (pr=15968)
Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
2008-07-04 export to doc file  EN
EN 50195:1996 (pr=5740)
Code of practice for the safe use of fully enclosed askarel-filled electrical equipment
1996-12-11 export to doc file  EN
EN 50216-10:2009 (pr=15199)
Power transformer and reactor fittings - Part 10: Oil-to-air heat exchangers
2009-03-06 export to doc file  EN  FR  DE
EN 50216-11:2008 (pr=20505)
Power transformer and reactor fittings - Part 11: Oil and winding temperature indicators
2008-09-19 export to doc file  EN  FR  DE
EN 50216-12:2011 (pr=20478)
Power transformer and reactor fittings - Part 12: Fans
2011-04-01 export to doc file  EN  FR  DE
EN 50216-1:2002 (pr=4783)
Power transformer and reactor fittings - Part 1: General
2002-01-11 export to doc file  EN
EN 50216-2:2002 (pr=216)
Power transformer and reactor fittings - Part 2: Gas and oil actuated relay for liquid immersed transformers and reactors with conservator
2002-01-11 export to doc file  EN
EN 50216-2:2002/A1:2002 (pr=14853)
Power transformer and reactor fittings - Part 2: Gas and oil actuated relay for liquid immersed transformers and reactors with conservator
2002-12-20 export to doc file  EN
EN 50216-3:2002 (pr=5601)
Power transformer and reactor fittings - Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion
2002-01-11 export to doc file  EN
EN 50216-3:2002/A2:2006 (pr=20479)
Power transformer and reactor fittings - Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion
2006-10-11 export to doc file  EN  FR  DE
EN 50216-4:2002 (pr=8159)
Power transformer and reactor fittings - Part 4: Basic accessories (earthing terminal, drain and filling devices, thermometer pocket, wheel assembly)
2002-01-11 export to doc file  EN
EN 50216-5:2002 (pr=11501)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2002-01-11 export to doc file  EN
EN 50216-5:2002/A2:2005 (pr=14950)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2005-05-26 export to doc file  EN  FR  DE
EN 50216-5:2002/A3:2006 (pr=20506)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2006-10-11 export to doc file  EN  FR  DE
EN 50216-6:2002 (pr=7656)
Power transformer and reactor fittings - Part 6: Cooling equipment - Removable radiators for oil-immersed transformers
2002-01-31 export to doc file  EN
EN 50216-7:2002 (pr=4784)
Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil
2002-01-18 export to doc file  EN
EN 50216-8:2005 (pr=14952)
Power transformer and reactor fittings - Part 8: Butterfly valves for insulating liquid circuits
2005-05-31 export to doc file  EN  FR  DE
EN 50216-8:2005/A1:2006 (pr=20507)
Power transformer and reactor fittings - Part 8: Butterfly valves for insulating liquid circuits
2006-10-11 export to doc file  EN  FR  DE
EN 50216-9:2009 (pr=15198)
Power transformer and reactor fittings - Part 9: Oil-to-water heat exchangers
2009-03-06 export to doc file  EN  FR  DE
EN 50225:1996 (pr=5741)
Code of practice for the safe use of fully enclosed oil-filled electrical equipment which may be contaminated with PCBs
1996-12-11 export to doc file  EN
EN 50299:2002 (pr=5214)
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV
2002-11-08 export to doc file  EN
EN 50464-1:2007 (pr=14814)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2007-04-20 export to doc file  EN  FR  DE
EN 50464-1:2007/A1:2012 (pr=22806)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2012-01-20 export to doc file  EN  DE
EN 50464-2-1:2007 (pr=14815)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-1: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - General requirements
2007-04-20 export to doc file  EN  FR  DE
EN 50464-2-2:2007 (pr=14816)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1
2007-04-20 export to doc file  EN  FR  DE
EN 50464-2-3:2007 (pr=14817)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-3: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
2007-04-20 export to doc file  EN  FR  DE
EN 50464-3:2007 (pr=20582)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the power rating of a transformer loaded with non-sinusoidal currents
2007-04-20 export to doc file  EN  FR  DE
EN 50464-4:2007 (pr=14819)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4: Requirements and tests concerning pressurised corrugated tanks
2007-04-20 export to doc file  EN  FR  DE
EN 50464-4:2007/A1:2011 (pr=22807)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4: Requirements and tests concerning pressurised corrugated tanks
2011-10-28 export to doc file  EN  FR  DE
EN 50541-1:2011 (pr=14820)
Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2011-04-29 export to doc file  EN  FR  DE
EN 50541-2:2013 (pr=22805)
Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 2: Determination of loadability of a transformer loaded with non-sinusoidal current
2013-06-21 export to doc file  EN  FR
EN 60076-10:2001 (pr=13164)
Power transformers - Part 10: Determination of sound levels
2001-07-10 export to doc file  EN  FR  DE
EN 60076-11:2004 (pr=15242)
Power transformers - Part 11: Dry-type transformers
2004-07-28 export to doc file  EN
EN 60076-13:2006 (pr=16727)
Power transformers - Part 13: Self-protected liquid-filled transformers
2006-10-04 export to doc file  EN  FR  DE
EN 60076-14:2013 (pr=24171)
Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
2013-10-25 export to doc file  EN  FR  DE
EN 60076-16:2011 (pr=22613)
Power transformers - Part 16: Transformers for wind turbines applications
2011-10-28 export to doc file  EN  FR  DE
EN 60076-18:2012 (pr=23523)
Power transformers - Part 18: Measurement of frequency response
2012-09-28 export to doc file  EN  FR  DE
EN 60076-1:1997 (pr=4846)
Power transformers - Part 1: General
1997-05-28 export to doc file  EN
EN 60076-1:1997/A12:2002 (pr=12118)
Power transformers - Part 1: General
2002-02-13 export to doc file  EN
EN 60076-1:1997/A1:2000 (pr=13258)
Power transformers - Part 1: General
2000-11-08 export to doc file  EN
EN 60076-1:2011 (pr=22467)
Power transformers - Part 1: General
2011-11-04 export to doc file  EN  FR  DE
EN 60076-2:2011 (pr=22468)
Power transformers - Part 2: Temperature rise for liquid-immersed transformers
2011-04-01 export to doc file  EN  FR  DE
EN 60076-3:2001 (pr=13537)
Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
2001-05-02 export to doc file  EN
EN 60076-3:2013 (pr=24097)
Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
2013-11-29 export to doc file  EN  FR  DE
EN 60076-4:2002 (pr=14207)
Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors
2002-09-10 export to doc file  EN
EN 60076-5:2006 (pr=16426)
Power transformers - Part 5: Ability to withstand short-circuit
2006-06-09 export to doc file  EN  FR  DE
EN 60076-6:2008 (pr=20669)
Power transformers - Part 6: Reactors
2008-07-22 export to doc file  EN  FR  DE
EN 60214-1:2003 (pr=14343)
Tap-changers - Part 1: Performance requirements and test methods
2003-04-11 export to doc file  EN
EN 61378-1:1998 (pr=8267)
Convertor transformers - Part 1: Transformers for industrial applications
1998-11-23 export to doc file  EN  EN  FR  DE
EN 61378-1:2011 (pr=22426)
Convertor transformers - Part 1: Transformers for industrial applications
2011-11-11 export to doc file  EN  FR  DE
EN 61378-2:2001 (pr=13165)
Convertor transformers - Part 2: Transformers for HVDC applications
2001-04-18 export to doc file  EN
HD 428.1 S1:1992/AC:2011 (pr=23798)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2011-10-21 export to doc file  EN  FR  DE
HD 538.1 S1:1992/AC:2011 (pr=23795)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2011-10-21 export to doc file  EN  FR  DE
HD 538.3 S1:1997 (pr=5744)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the power rating of a transformer loaded with non- sinusoidal current
1997-05-06 export to doc file  EN

export to xls fileexport to xls file

CLC/TC 14 Maintenance cycle

 sort down
Publication number
sort upsort down
Date of Publication
Review date
sort upsort down
Result date
sort upsort down
Technical Comittee
sort upsort down
Project in progress
CLC/TR 50453:2007 (pr=16657)
Evaluation of electromagnetic fields around power transformers
2007-05-162012-05-162015-05-16CLC/TC 14 
CLC/TR 50462:2008 (pr=15968)
Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
2008-07-042013-07-042016-07-04CLC/TC 14 
EN 50195:1996 (pr=5740)
Code of practice for the safe use of fully enclosed askarel-filled electrical equipment
1996-12-112001-12-112004-12-11CLC/TC 14 
EN 50216-10:2009 (pr=15199)
Power transformer and reactor fittings - Part 10: Oil-to-air heat exchangers
2009-03-062014-03-062017-03-06CLC/TC 14 
EN 50216-11:2008 (pr=20505)
Power transformer and reactor fittings - Part 11: Oil and winding temperature indicators
2008-09-192013-09-192016-09-19CLC/TC 14 
EN 50216-12:2011 (pr=20478)
Power transformer and reactor fittings - Part 12: Fans
2011-04-012016-04-012019-04-01CLC/TC 14 
EN 50216-1:2002 (pr=4783)
Power transformer and reactor fittings - Part 1: General
2002-01-112007-01-112010-01-11CLC/TC 14 
EN 50216-2:2002 (pr=216)
Power transformer and reactor fittings - Part 2: Gas and oil actuated relay for liquid immersed transformers and reactors with conservator
2002-01-112007-01-112010-01-11CLC/TC 14 
EN 50216-2:2002/A1:2002 (pr=14853)
Power transformer and reactor fittings - Part 2: Gas and oil actuated relay for liquid immersed transformers and reactors with conservator
2002-12-202007-12-202010-12-20CLC/TC 14 
EN 50216-3:2002 (pr=5601)
Power transformer and reactor fittings - Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion
2002-01-112007-01-112010-01-11CLC/TC 14 
EN 50216-3:2002/A2:2006 (pr=20479)
Power transformer and reactor fittings - Part 3: Protective relay for hermetically sealed liquid-immersed transformers and reactors without gaseous cushion
2006-10-112011-10-112014-10-11CLC/TC 14 
EN 50216-4:2002 (pr=8159)
Power transformer and reactor fittings - Part 4: Basic accessories (earthing terminal, drain and filling devices, thermometer pocket, wheel assembly)
2002-01-112010-03-012013-03-01CLC/TC 14prEN 50216-4:2013
EN 50216-5:2002 (pr=11501)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2002-01-112007-01-112010-01-11CLC/TC 14 
EN 50216-5:2002/A2:2005 (pr=14950)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2005-05-262010-05-262013-05-26CLC/TC 14 
EN 50216-5:2002/A3:2006 (pr=20506)
Power transformer and reactor fittings - Part 5: Liquid level, pressure and flow indicators, pressure relief devices and dehydrating breathers
2006-10-112011-10-112014-10-11CLC/TC 14 
EN 50216-6:2002 (pr=7656)
Power transformer and reactor fittings - Part 6: Cooling equipment - Removable radiators for oil-immersed transformers
2002-01-312007-01-312010-01-31CLC/TC 14 
EN 50216-7:2002 (pr=4784)
Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil
2002-01-182007-01-182010-01-18CLC/TC 14 
EN 50216-8:2005 (pr=14952)
Power transformer and reactor fittings - Part 8: Butterfly valves for insulating liquid circuits
2005-05-312010-05-312013-05-31CLC/TC 14 
EN 50216-8:2005/A1:2006 (pr=20507)
Power transformer and reactor fittings - Part 8: Butterfly valves for insulating liquid circuits
2006-10-112011-10-112014-10-11CLC/TC 14 
EN 50216-9:2009 (pr=15198)
Power transformer and reactor fittings - Part 9: Oil-to-water heat exchangers
2009-03-062014-03-062017-03-06CLC/TC 14 
EN 50225:1996 (pr=5741)
Code of practice for the safe use of fully enclosed oil-filled electrical equipment which may be contaminated with PCBs
1996-12-112001-12-112004-12-11CLC/TC 14 
EN 50299:2002 (pr=5214)
Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV
2002-11-082012-08-062015-08-06CLC/TC 14prEN 50299-1:2013
EN 50464-1:2007 (pr=14814)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2007-04-202012-11-142015-11-14CLC/TC 14FprEN 50588-1:201X
EN 50464-1:2007/A1:2012 (pr=22806)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2012-01-202012-11-142015-11-14CLC/TC 14FprEN 50588-1:201X
EN 50464-2-1:2007 (pr=14815)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-1: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - General requirements
2007-04-202012-04-202015-04-20CLC/TC 14 
EN 50464-2-2:2007 (pr=14816)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1
2007-04-202012-04-202015-04-20CLC/TC 14 
EN 50464-2-3:2007 (pr=14817)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-3: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
2007-04-202012-04-202015-04-20CLC/TC 14 
EN 50464-3:2007 (pr=20582)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the power rating of a transformer loaded with non-sinusoidal currents
2007-04-202012-04-202015-04-20CLC/TC 14 
EN 50464-4:2007 (pr=14819)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4: Requirements and tests concerning pressurised corrugated tanks
2007-04-202012-04-202015-04-20CLC/TC 14 
EN 50464-4:2007/A1:2011 (pr=22807)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 4: Requirements and tests concerning pressurised corrugated tanks
2011-10-282016-10-282019-10-28CLC/TC 14 
EN 50541-1:2011 (pr=14820)
Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
2011-04-292012-11-142015-11-14CLC/TC 14FprEN 50588-1:201X
EN 50541-2:2013 (pr=22805)
Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 2: Determination of loadability of a transformer loaded with non-sinusoidal current
2013-06-212018-06-212021-06-21CLC/TC 14 
EN 60076-10:2001 (pr=13164)
Power transformers - Part 10: Determination of sound levels
2001-07-10 2016-11-05CLC/TC 14FprEN 60076-10:2013
EN 60076-11:2004 (pr=15242)
Power transformers - Part 11: Dry-type transformers
2004-07-28 2012-07-28CLC/TC 14 
EN 60076-13:2006 (pr=16727)
Power transformers - Part 13: Self-protected liquid-filled transformers
2006-10-04 2014-10-04CLC/TC 14 
EN 60076-14:2013 (pr=24171)
Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials
2013-10-25 2021-10-25CLC/TC 14 
EN 60076-16:2011 (pr=22613)
Power transformers - Part 16: Transformers for wind turbines applications
2011-10-28 2019-10-28CLC/TC 14 
EN 60076-18:2012 (pr=23523)
Power transformers - Part 18: Measurement of frequency response
2012-09-28 2020-09-28CLC/TC 14 
EN 60076-1:1997 (pr=4846)
Power transformers - Part 1: General
1997-05-28 2011-11-04CLC/TC 14EN 60076-1:2011
EN 60076-1:1997/A12:2002 (pr=12118)
Power transformers - Part 1: General
2002-02-132009-05-262011-11-04CLC/TC 14EN 60076-1:2011
EN 60076-1:1997/A1:2000 (pr=13258)
Power transformers - Part 1: General
2000-11-08 2011-11-04CLC/TC 14EN 60076-1:2011
EN 60076-1:2011 (pr=22467)
Power transformers - Part 1: General
2011-11-04 2019-11-04CLC/TC 14 
EN 60076-2:2011 (pr=22468)
Power transformers - Part 2: Temperature rise for liquid-immersed transformers
2011-04-01 2019-04-01CLC/TC 14 
EN 60076-3:2001 (pr=13537)
Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
2001-05-02 2013-11-29CLC/TC 14EN 60076-3:2013
EN 60076-3:2013 (pr=24097)
Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
2013-11-29 2021-11-29CLC/TC 14 
EN 60076-4:2002 (pr=14207)
Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors
2002-09-10 2010-09-10CLC/TC 14 
EN 60076-5:2006 (pr=16426)
Power transformers - Part 5: Ability to withstand short-circuit
2006-06-09 2014-06-09CLC/TC 14 
EN 60076-6:2008 (pr=20669)
Power transformers - Part 6: Reactors
2008-07-22 2016-07-22CLC/TC 14 
EN 60214-1:2003 (pr=14343)
Tap-changers - Part 1: Performance requirements and test methods
2003-04-11 2016-05-07CLC/TC 14FprEN 60214-1:2013
EN 61378-1:1998 (pr=8267)
Convertor transformers - Part 1: Transformers for industrial applications
1998-11-23 2011-11-11CLC/TC 14EN 61378-1:2011
EN 61378-1:2011 (pr=22426)
Convertor transformers - Part 1: Transformers for industrial applications
2011-11-11 2019-11-11CLC/TC 14 
EN 61378-2:2001 (pr=13165)
Convertor transformers - Part 2: Transformers for HVDC applications
2001-04-18 2009-04-18CLC/TC 14 
HD 428.1 S1:1992/AC:2011 (pr=23798)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2011-10-212016-10-212019-10-21CLC/TC 14 
HD 538.1 S1:1992/AC:2011 (pr=23795)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2011-10-212016-10-212019-10-21CLC/TC 14 
HD 538.3 S1:1997 (pr=5744)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 3: Determination of the power rating of a transformer loaded with non- sinusoidal current
1997-05-062002-05-062005-05-06CLC/TC 14 

export to xls file

TC 3 Project files


CLC/TC 14 TC/SC in figures

Current Stage
Year
Year -1
Year -2
Year -3
Year -4
Year >5
Committee stage200000
Enquiry stage300000
Approval stage110000
Published0329041
Withdrawn0000046

CLC/TC 14 Figures overall

Total publications
32
Published in last 3 years
7
Total work in progress
15
Total proposals
0
export to xls file

CLC/TC 14 Environment

Reference
Clause
Categories - Aspects
Product Life Cycle
Information
Confirmed
HD 428.1 S1:1992 (pr=205)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2.8 Energy use Use B2B Y
2.8 Noise emissions Use B2B
HD 538.1 S1:1992 (pr=212)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV
2.7 Energy use Use B2B Y
2.7 Noise emissions Use B2B
HD 538.2 S1:1995 (pr=214)
Three-phase dry-type distribution transformers 50 Hz, from 100 to 2500 kVA, with highest voltage for equipment not exceeding 36 kV - Part 2: Supplementary requirements for transformers with highest voltage for equipment equal to 36 kV
2.7 Energy use Use B2B Y
2.7 Noise emissions Use B2B
EN 50195:1996 (pr=5740)
Code of practice for the safe use of fully enclosed askarel-filled electrical equipment
5 Hazardous substances Manufacturing, Use, Disposal B2B, B2C Y
12 Hazardous substances Manufacturing, Use B2B, B2C
14 Hazardous substances Manufacturing B2B
4 Hazardous substances Use B2B, DfE
All Hazardous substances Use B2B
6 Risks to the environment from accidents or misuse Use B2B
13 Waste Disposal B2C
EN 50216-7:2002 (pr=4784)
Power transformer and reactor fittings - Part 7: Electric pumps for transformer oil
4.6 Noise emissions Use B2B Y
EN 50225:1996 (pr=5741)
Code of practice for the safe use of fully enclosed oil-filled electrical equipment which may be contaminated with PCBs
14 Hazardous substances Manufacturing B2B Y
4 Hazardous substances Use B2B, DfE
All Hazardous substances Use B2C
6 Risks to the environment from accidents or misuse Use B2C
13 Waste Disposal B2C
CLC/TR 50462:2008 (pr=15968)
Rules for the determination of uncertainties in the measurement of the losses on power transformers and reactors
All Energy use Use B2B Y
EN 50464-1:2007 (pr=14814)
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
6 Energy use Use B2B Y
3.8 Energy use Use B2B
3.8 Noise emissions Use B2B
EN 60076-1:1997/A12:2002 (pr=12118)
Power transformers - Part 1: General
Annex ZB.2.3 Noise emissions Use B2B, DfE Y
EN 60076-10:2001 (pr=13164)
Power transformers - Part 10: Determination of sound levels
All Noise emissions Use B2B, DfE Y
EN 60076-11:2004 (pr=15242)
Power transformers - Part 11: Dry-type transformers
Annex A.2.3 Emissions to air Use B2B, DfE Y
Annex A.2.3 Noise emissions Use B2B, DfE
24 Noise emissions Use B2B
EN 60289:1994/A11:2002 (pr=12119)
Reactors
Annex ZB.2.3 Noise emissions Use B2B Y
EN 61378-1:1998 (pr=8267)
Convertor transformers - Part 1: Transformers for industrial applications
6.3 Energy use Use B2B Y
5 Energy use Use B2B
EN 61378-2:2001 (pr=13165)
Convertor transformers - Part 2: Transformers for HVDC applications
7 Energy use Use B2B Y
9 Noise emissions Use B2B

export to xls file

CLC/TC 14 EU Directive(s)

Reference
Stage code
Directive
OJ Status
OJ Reference
Mandate
EN 50195:1996 (pr=5740)
Code of practice for the safe use of fully enclosed askarel-filled electrical equipment
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NOJ
EN 50225:1996 (pr=5741)
Code of practice for the safe use of fully enclosed oil-filled electrical equipment which may be contaminated with PCBs
6060 2006/95/EC
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits
NOJ
FprEN 50588-1:201X (pr=24468)
Medium voltage transformers 50 Hz, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
4092 2009/125/EC
Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products
LEG
FprEN 50629:201X (pr=25005)
Energy efficiency of transformers with Um greater than 36 kV
4092 2009/125/EC
Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products
LEG