CENELEC

Project
| Reference | EN 50130-5:2011 |
|---|---|
| Title | Alarm systems - Part 5: Environmental test methods |
| Project Number | 22701 |
| Abstract/Scope | This European Standard specifies environmental test methods to be used for testing the system components of the following alarm systems, intended for use in and around buildings: - intruder alarm systems; - hold-up alarm systems; - social alarm systems; - CCTV systems, for security applications; - access control systems, for security applications; - alarm transmission systems 1). This European Standard specifies three equipment classes (fixed, movable & portable equipment) and four environmental classes. The environmental classes only include the general service environments envisaged for equipment installed in typical residential, commercial and industrial environments. It may be necessary for the product standard to require additional or different environmental tests or severities where a) there could be specific environmental problems (e.g. some different severities may be required for break glass detectors stuck to glass windows, due to the local extremes of temperature and humidity), b) the test exposure falls within the intended detection phenomenon of the detector (e.g. during a vibration test on a seismic detector). In order to provide reproducible test methods and to avoid the proliferation of technically similar test methods, the test procedures have been chosen, where possible, from internationally accepted standards (e.g. IEC publications). For specific guidance on these tests, reference should be made to the appropriate document, which is indicated in the relevant sub section. For more general guidance and background information on environmental testing, reference should be made to EN 60068 1 and to the EN 60068 3 series. This European Standard does not specify a) the requirements or performance criteria to be applied, which should be specified in the relevant product standard, b) special tests only applicable to a particular device (e.g. the effects of turbulent air draughts on ultrasonic movement detectors), c) basic safety requirements, such as protection against electrical shocks, unsafe operation, insulation coordination and related dielectric tests, d) tests relating to deliberate acts of damage or tampering. |
| Status |
Published
|
Status
| Current Stage code | 6060 |
|---|---|
| Current Stage code date | 2011-06-17 |
| Current Stage code deadline | 2012-06-13 |
| Deadline date for vote | 2011-11-30 |
Legal
| Directive(s) | |
|---|---|
| Mandate(s) | |
| Order Voucher |
Details
| IEC Technical Body | |
|---|---|
| Reference Document | |
| ICS | 13.320 - Alarm and warning systems 29.020 - Electrical engineering in general |
| Keywords | Alarm; Environment |
| Note | Supersedes EN 50130-5:1998 |
| A-Deviation(s) | |
| Special National Condition(s) |
Environment
|
Clause
|
Categories - Aspects
|
Product Life Cycle
|
Information
|
|---|
History
|
Stage
|
Date
|
Deadline Date
|
Documents
|
|---|---|---|---|
| 6060 | 2011-06-17 | 2012-06-13 | |
| 5099 | 2011-06-13 | 2011-07-11 | |
| 5060 | 2011-05-09 | 2011-05-30 | |
| 5020 | 2011-03-04 | 2011-05-06 | |
| 4090 | 2010-11-12 | 2011-03-04 | |
| 4060 | 2010-09-07 | 2010-12-07 | |
| 4020 | 2010-03-12 | 2010-09-03 | |
| 3099 | 2009-12-01 | 2010-03-22 | |
| 1099 | 2009-12-01 | 2010-03-01 | |
| 1000 | 2009-10-19 | 2009-11-30 |
Implementation Dates
| date of Ratification (DOR) (1) | 2011-06-13 |
|---|---|
| date of Availability (DAV) (2) | 2011-06-17 |
| date of Announcement (DOA) (3) | 2011-12-13 |
| date of Publication (DOP) (4) | 2012-06-13 |
| date of Withdrawal (DOW) (5) | 2014-06-13 |
Relations
| Supersedes | EN 50130-5:1998 |
|---|---|
| Superseded by | |
| Normative reference (6) |
(1) Date of ratification (dor) date when the Technical Board notes the approval of an EN (and HD for CENELEC), from which time the standard may be said to be approved
(2) Date of availability (dav) date when the definitive text in the official language versions of an approved CEN/CENELEC publication is distributed by the Central Secretariat
(3) Date of announcement (doa) latest date by which the existence of an EN (and HD for CENELEC), a TS or a CWA has to be announced at national level
(4) Date of publication (dop) latest date by which an EN has to be implemented at national level by publication of an identical national standard or by endorsement
(5) Date of withdrawal (dow) latest date by which national standards conflicting with an EN (and HD for CENELEC) have to be withdrawn
(6) This list of normative references is purely indicative. The only official list of normative reference is the list of the published standard.