International Standards and Conformity Assessment for all electrical, electronic and related technologies

 

Project

Reference EN 50131-1:2006/IS2:2010
Title Alarm systems - Intrusion and hold-up systems - Part 1: System requirements
Project Number 22813
Abstract/Scope This European Standard specifies the requirements for Intrusion and Hold-up Alarm Systems installed in buildings using specific or non-specific wired interconnections or wire-free interconnections. These requirements also apply to the components of an I&HAS installed in a building which are normally mounted on the external structure of a building e.g. ancillary control equipment or warning devices. The standard does not include requirements for exterior I&HAS. This standard specifies performance requirements for installed I&HAS but does not include requirements for design, planning, installation, operation or maintenance. These requirements also apply to I&HAS sharing means of detection, triggering, interconnection, control, communication and power supplies with other applications. The functioning of an I&HAS shall not be adversely influenced by other applications. Requirements are specified for I&HAS components where the relevant environment is classified. This classification describes the environment in which an I&HAS component may be expected to function as designed. When the requirements of the four environmental classes are inadequate, due to the extreme conditions experienced in certain geographic locations, special national conditions are given in Annex A. General environmental requirements for I&HAS components are described in Clause 7. The requirements of this European Standard also apply to IAS and HAS when these systems are installed independently. When an I&HAS does not include functions relating to the detection of intruders, the requirements relating to intrusion detection do not apply. When an I&HAS does not include functions relating to hold-up, the requirements relating to hold-up do not apply. NOTE Unless otherwise stated the abbreviation I&HAS is intended to also mean IAS and HAS.
Status
Published

Status

Current Stage code 6060
Current Stage code date 2010-08-06
Current Stage code deadline  
Deadline date for vote  

Legal

Directive(s)  
Mandate(s)  
Order Voucher  

Details

IEC Technical Body  
Reference Document  
ICS 13.310 - Protection against crime
Keywords Alarm system; Intrusion system
Note Supersedes EN 50131-1:2006/IS1:2009
A-Deviation(s)  
Special National Condition(s)  

Environment

Clause
Categories - Aspects
Product Life Cycle
Information

History

Stage
Date
Deadline Date
Documents
6060 2010-08-06   export to doc file  EN
5099 2010-07-09 2010-11-09  
5060 2010-06-28 2010-07-09 export to doc file  EN
5020 2010-01-22 2010-06-25 export to doc file  EN
1090 2009-12-24 2010-01-24  

Implementation Dates

date of Ratification (DOR) (1) 2010-07-09
date of Availability (DAV) (2) 2010-08-06
date of Announcement (DOA) (3) -
date of Publication (DOP) (4) -
date of Withdrawal (DOW) (5) -

Relations

Supersedes EN 50131-1:2006/IS1:2009
Superseded by  
Normative reference (6)  

(1) Date of ratification (dor) date when the Technical Board notes the approval of an EN (and HD for CENELEC), from which time the standard may be said to be approved


(2) Date of availability (dav) date when the definitive text in the official language versions of an approved CEN/CENELEC publication is distributed by the Central Secretariat


(3) Date of announcement (doa) latest date by which the existence of an EN (and HD for CENELEC), a TS or a CWA has to be announced at national level


(4) Date of publication (dop) latest date by which an EN has to be implemented at national level by publication of an identical national standard or by endorsement


(5) Date of withdrawal (dow) latest date by which national standards conflicting with an EN (and HD for CENELEC) have to be withdrawn


(6) This list of normative references is purely indicative. The only official list of normative reference is the list of the published standard.