International Standards and Conformity Assessment for all electrical, electronic and related technologies

 

Project

Reference EN 61095:2009
Title Electromechanical contactors for household and similar purposes
Project Number 21397
Abstract/Scope IEC 61095:2009 applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V a.c. (between phases) with rated operational currents less than or equal to 63 A for utilization category AC-7a and 32 A for utilization categories AC-7b and AC-7c, and rated conditional short-circuit current less than or equal to 6 kA. This second edition cancels and replaces the first edition published in 1992 and its Amendment 1 (2000), and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - deletion of switching overvoltages requirements, - addition of a new utilization category AC-7c: switching of compensated electric discharge lamp control, - measuring of Uimp required, but the marking is not required if Uimp equal to 4 kV, - improvement regarding marking concerning direction of movement, - improvement of dielectric properties, - test of resistance to humidity referred to IEC 60068-2-78 instead of IEC 60068-2-3, - amendment to Table B.1 regarding test sequences, - deletion of Table F.2 regarding the correspondence between the nominal voltage of the supply system and the contactor rated impulse withstand voltage, - addition of a new Annex H (normative): degrees of protection of enclosed contactor, - addition of a new Annex I (normative): requirements and tests for equipment with protective separation.
Status
Published

Status

Current Stage code 6060
Current Stage code date 2009-03-20
Current Stage code deadline 2009-12-01
Deadline date for vote  

Legal

Directive(s) LVD (2006/95/EC)
Mandate(s)  
Order Voucher  

Details

IEC Technical Body IEC/SC 17B
Reference Document IEC 61095:2009 (EQV)
ICS 29.120.99 - Other electrical accessories
29.130.20 - Low voltage switchgear and controlgear
Keywords Contactor; Electromechanical; Household
Note  
A-Deviation(s)  
Special National Condition(s)  

Environment

Clause
Categories - Aspects
Product Life Cycle
Information

History

Stage
Date
Deadline Date
Documents
6060 2009-03-20 2009-12-01 export to doc file  EN  FR  DE
5099 2009-03-01 2009-05-01  
5060 2009-01-13 2009-01-27 export to doc file  EN
5020 2008-11-07 2009-01-09  
3090 2008-01-25 2008-04-30  
5060 2008-01-14 2008-01-28 export to doc file  EN
5020 2007-07-27 2008-01-11  
1090 2007-07-24 2007-07-27  

Implementation Dates

date of Ratification (DOR) (1) 2009-03-01
date of Availability (DAV) (2) 2009-03-20
date of Announcement (DOA) (3) 2009-06-01
date of Publication (DOP) (4) 2009-12-01
date of Withdrawal (DOW) (5) 2012-03-01

Relations

Supersedes EN 61095:1993
EN 61095:1993/corrigendum Mar. 1993
EN 61095:1993/A1:2000
EN 61095:1993/A1:2000/corrigendum Apr. 2001
Superseded by  
Normative reference (6) ISO 2039-2:1987
ISO 7000:2004
IEC 60028:1925
IEC 60050-151:2001
IEC 60050-441:1984
IEC 60050-604:1987
IEC 60050-826:2004
EN 60068-2-78:2001
EN 60073:2002
EN 60085:2008
EN 60099-1:1994
A1:1999
EN 60112:2003
EN 60216-1:2001
HD 60364-4-444:2010
corr. July 2010
corr.
EN 60445:2007
EN 60447:2004
EN 60529:1991
corr. May 1993
A1:2000
EN 60664-1:2007
EN 60695-2-10:2001
EN 60695-2-11:2001
EN 60695-11-10:1999
A1:2003
EN 60947-1:2007
EN 60947-4-1:2001
A1:2002
A2:2005
EN 60947-5-1:2004
corr. November 2004
corr. July 2005
EN 61140:2002
A1:2006
EN 61180-1:1994
IEC 60417-DB

(1) Date of ratification (dor) date when the Technical Board notes the approval of an EN (and HD for CENELEC), from which time the standard may be said to be approved


(2) Date of availability (dav) date when the definitive text in the official language versions of an approved CEN/CENELEC publication is distributed by the Central Secretariat


(3) Date of announcement (doa) latest date by which the existence of an EN (and HD for CENELEC), a TS or a CWA has to be announced at national level


(4) Date of publication (dop) latest date by which an EN has to be implemented at national level by publication of an identical national standard or by endorsement


(5) Date of withdrawal (dow) latest date by which national standards conflicting with an EN (and HD for CENELEC) have to be withdrawn


(6) This list of normative references is purely indicative. The only official list of normative reference is the list of the published standard.