CENELEC

Project
| Reference | EN 50264-3-2:2008 |
|---|---|
| Title | Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables |
| Project Number | 15254 |
| Abstract/Scope | EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40); • 0,6/1 kV screened or unscreened, (1,5 mm2 to 50 mm2, 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 C and a maximum temperature for short circuit conditions of 200 C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-2 should be read in conjunction with Part 1 “General requirements”. |
| Status |
Published
|
Status
| Current Stage code | 6060 |
|---|---|
| Current Stage code date | 2008-06-27 |
| Current Stage code deadline | 2009-03-01 |
| Deadline date for vote | 2007-12-05 |
Legal
| Directive(s) | |
|---|---|
| Mandate(s) | |
| Order Voucher |
Details
| IEC Technical Body | IEC/TC 20 |
|---|---|
| Reference Document | |
| ICS | 13.220.20 - Fire protection 29.060.20 - Cables 45.060.01 - Railway rolling stock in general |
| Keywords | Railway applications; Cable; Rolling stock; Fire performance; Insulation |
| Note | |
| A-Deviation(s) | |
| Special National Condition(s) |
Environment
|
Clause
|
Categories - Aspects
|
Product Life Cycle
|
Information
|
|---|
History
|
Stage
|
Date
|
Deadline Date
|
Documents
|
|---|---|---|---|
| 6060 | 2008-06-27 | 2009-03-01 | |
| 5099 | 2008-03-01 | 2008-07-01 | |
| 5061 | 2008-01-28 | 2008-03-01 | |
| 5060 | 2007-11-26 | 2007-12-27 | |
| 5020 | 2007-09-21 | 2007-11-23 | |
| 4099 | 2006-05-24 | 2007-08-24 | |
| 4060 | 2006-01-27 | 2006-03-27 | |
| 4020 | 2005-07-22 | 2006-01-20 | |
| 3099 | 2004-10-28 | 2005-03-28 | |
| 2020 | 2003-05-27 | 2004-09-30 | |
| 2020 | 2002-05-29 | 2002-11-29 |
Implementation Dates
| date of Ratification (DOR) (1) | 2008-03-01 |
|---|---|
| date of Availability (DAV) (2) | 2008-06-27 |
| date of Announcement (DOA) (3) | 2008-09-01 |
| date of Publication (DOP) (4) | 2009-03-01 |
| date of Withdrawal (DOW) (5) | 2011-03-01 |
Relations
| Supersedes | |
|---|---|
| Superseded by | |
| Normative reference (6) |
HD 308 S2:2001
EN 50264-1:2008 EN 50266-2-4:2001 EN 50266-2-5:2001 EN 50305:2002 EN 50334:2001 EN 60228:2005 EN 60332-1-2:2004 EN 60811-1-1:1995 EN 60811-1-2:1995 EN 60811-1-3:1995 EN 60811-1-4:1995 EN 60811-2-1:1998 EN 61034-2:2005 |
(1) Date of ratification (dor) date when the Technical Board notes the approval of an EN (and HD for CENELEC), from which time the standard may be said to be approved
(2) Date of availability (dav) date when the definitive text in the official language versions of an approved CEN/CENELEC publication is distributed by the Central Secretariat
(3) Date of announcement (doa) latest date by which the existence of an EN (and HD for CENELEC), a TS or a CWA has to be announced at national level
(4) Date of publication (dop) latest date by which an EN has to be implemented at national level by publication of an identical national standard or by endorsement
(5) Date of withdrawal (dow) latest date by which national standards conflicting with an EN (and HD for CENELEC) have to be withdrawn